NSN 5840-01-106-0349 D3021643, D30-21643, 01-106-0349
Product Details | NARROW BAND AMPLIFI
5840-01-106-0349
Part Alternates: D3021643, D30-21643, 5840-01-106-0349, 01-106-0349, 5840011060349, 011060349
Communication, Detection, and Coherent Radiation Equipment | Radar Equipment, Except Airborne
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
58 | 10 JAN 1981 | 01-106-0349 | 77777 ( ) |
Cross Reference | NSN 5840-01-106-0349
Part Number | Cage Code | Manufacturer |
---|---|---|
D30-21643 | 01238 | COMMUNICATIONS AND POWER INDUSTRIES SOLID STATE PRODUCTS DIV |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5840-01-106-0349
Related Products | NSN 5840-01-106-0349
Technical Data | NSN 5840-01-106-0349
Characteristic | Specifications |
---|---|
GENERAL CHARACTERISTICS ITEM DESCRIPTION | INTERMEDIATE FREQUENCY SUB-ASSEMBLY,70 MHZ NARROW BAND AMPLIFIER 1; CAVITY,MACHINED AED 1 |
MANUFACTURERS CODE | 01238 |
DESIGN CONTROL REFERENCE | D30-21643 |
Restrictions/Controls & Freight Information | NSN 5840-01-106-0349
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | N | The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input). |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 060500 | ELECTRICAL EQUIPMENT GROUP |
Less than car load rating | ||
Less than truck load rating | Z | No Rating |
Water commodity Code | 72D | unknown |
Originating Activity Code | PA | Marine Corps Logistics Base Albany, GA 31704-1128 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | 2 | Arms/Weapons (all types including Inert Component Parts). When a 2 is indicated in the first position, then the special handling code must be determined from table 85 , part 1. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 2 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5840-01-106-0349
Category | Code | Description |
---|---|---|
Stores Account Code | 2 | Marine Corps Appropriation Stores Account Secondary Items. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | 4 | Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665 |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Operational Test Code | 2 | Items of equipment which require the performance of special procedures are not controlled through the MOWASP special handling suspense routine by USMC/Serial Numbers, (except small arms which are controlled by serial numbers but are assigned OTC 2). Normally OTC 2 items of equipments are small arms, engines (except small engines coded SAC-1 which are non-technical), pumps, generators, electronic equipments and major components/subassemblies of weapon systems, etc. Electronic Circuit Cards and other items which have received Level A packing will only be assigned an OTC when an operational test is mandatory prior to issue. |
Physical Category Code | 1 | Bin |
Source of Supply | MPB | Commanding General Marine Corps Logistics Command 566-2, Bldg. 3700 Albany, GA 31704-5000 |
Agency | DM | U.S. Marine Corps |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | D | Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level. |
Acquisition Advice Codes | U | LEAD SERVICE-MANAGED As a minimum provides procurement, disposal, and single submitter functions. Wholesale logistics responsibilities which are to be performed by the PICA in support of SICA are defined by the SICA NIMS Code. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |