Product Details | INTERCOMMUNICATION STATION

5831-00-836-6982 An item which may provide two-way amplified voice communications when connected to one or more like stations directly or via intermediate control equipment; includes loudspeaker (which may be used as a loudspeaker or microphone), signalling devices, amplifier and station selector switches. May include separate microphone, earphone, handset or headset. See also, TELEPHONE CONNECTING STATION.20258300062Intercommunication and Public Address Systems, Except Airborne58310055Intercommunication and Public Address Systems, Airborne

Part Alternates: LS460AIC, 128518, 5458186005, 545-8186-005, 5831-00-836-6982, 00-836-6982, 5831008366982, 008366982

Communication, Detection, and Coherent Radiation Equipment | Intercommunication and Public Address Systems, Airborne

Supply Group (FSG) NSN Assign. NIIN
58 01 JAN 1963 00-836-6982

Cross Reference | NSN 5831-00-836-6982

Part Number Cage Code Manufacturer
128518 06481 NORTHROP GRUMMAN SYSTEMS CORPORATION
545-8186-005 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
545-8186-005 98738 HERLEY CHICAGO DBA STEWART WARNER ELECTRONICS
LS460AIC 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5831-00-836-6982

Technical Data | NSN 5831-00-836-6982

Characteristic Specifications
AC VOLTAGE RATING 26.0 VOLTS NOMINAL
FREQUENCY RATING 380.0 HERTZ MINIMUM 420.0 HERTZ MAXIMUM
PHASE SINGLE
DC VOLTAGE RATING 27.5 VOLTS NOMINAL
INTERNAL BATTERY ACCOMMODATION NOT INCLUDED
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME INTERCOMMUNICATION STATION
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER LS-460/AIC
ELECTRICAL TRANSMISSION TYPE WIRE
AMPLIFIER INCLUDED
USAGE DESIGN INDOOR
ALL STATION POSITION NOT INCLUDED
III FSC APPLICATION DATA INTEGRATED ELECTRONIC CENTRAL
MANUFACTURERS CODE 13499
DESIGN CONTROL REFERENCE 545-8186-005

Restrictions/Controls & Freight Information | NSN 5831-00-836-6982

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:CMunitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information

Management | NSN 5831-00-836-6982

Category Code Description
Special Material IDBF (JSL Items) FIGHTERAIRCRAFT(F4)
Issue Repair, or RequisitionARRepairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved.
Source of SupplyN32Naval Inventory Control Point
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityHDepot Level Reparable
Acquisition Advice CodesCSERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each