NSN 5821-01-413-6092 5030084-35, 01-413-6092, 503008435
Product Details | CONTROL-CONVERTER
5821-01-413-6092 A single component which performs the dual function of determining the mode of operation of another item, and changes electrical input signals into a related mechanical form, such as shaft position.20414300037Guided Missile Remote Control Systems58110042Other Cryptologic Equipment and Components58200061Radio and Television Communication Equipment, Except Airborne58210054Radio and Television Communication Equipment, Airborne
Part Alternates: 5030084-35, 5821-01-413-6092, 01-413-6092, 5821014136092, 503008435, 014136092
Communication, Detection, and Coherent Radiation Equipment | Radio and Television Communication Equipment, Airborne
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
58 | 18 MAY 1995 | 01-413-6092 | 60299 ( CONTROL-CONVERTER ) |
Cross Reference | NSN 5821-01-413-6092
Part Number | Cage Code | Manufacturer |
---|---|---|
5030084-35 | 82577 | RAYTHEON COMPANY DBA RAYTHEON |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5821-01-413-6092
Related Products | NSN 5821-01-413-6092
Technical Data | NSN 5821-01-413-6092
Characteristic | Specifications |
---|---|
III END ITEM IDENTIFICATION | AIRCRAFT MODEL F-14D |
MANUFACTURERS CODE | 82577 |
DESIGN CONTROL REFERENCE | 5030084-35 |
Restrictions/Controls & Freight Information | NSN 5821-01-413-6092
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | J | 100.2 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | ||
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5821-01-413-6092
Category | Code | Description |
---|---|---|
Cognizance Codes | 7R | Aeronautical Depot Level Repairable Spares Naval Inventory Control Point, Philadelphia |
Special Material ID | GR | APG-71 Airborne Radar System |
Issue Repair, or Requisition | AR | Repairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved. |
Special Material Content | 2 | Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item |
Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
Agency | DN | Department of the Navy |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | H | Depot Level Reparable |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |