Product Details | REFERENCE SIGNAL GENERATOR

5821-00-068-9696 An electronic device which produces precise signals accurately related to a quantity such as time. The output signals are permanently connected into and are essential to the operation of other devices or equipments. Excludes items used in testing or alignment operations. See GENERATOR, SIGNAL and TIME SIGNAL SET.20258950037Miscellaneous Communication Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: SG-572/ACC-3, SG572ACC3, 0100398001, 01-00398-001, 5821-00-068-9696, 00-068-9696, 5821000689696, 000689696

Communication, Detection, and Coherent Radiation Equipment | Radio and Television Communication Equipment, Airborne

Supply Group (FSG) NSN Assign. NIIN
58 01 JAN 1963 00-068-9696

Drawings & Photos | NSN 5821-00-068-9696


Demand History | NSN 5821-00-068-9696

Part Number Request Date QTY Origin
5821-00-068-9696 2007-11-317 1 US

Cross Reference | NSN 5821-00-068-9696

Part Number Cage Code Manufacturer
01-00398-001 00724 RAYTHEON COMPANY DBA RAYTHEON
SG-572/ACC-3 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5821-00-068-9696

Technical Data | NSN 5821-00-068-9696

Characteristic Specifications
FREQUENCY PER CHANNEL 256.0 KILOHERTZ NOMINAL OPERATING CHANNEL
SIGNAL DATA TYPE PER CHANNEL OPERATING CHANNEL TIME
MAXIMUM CONTINUOUS OPERATING TIME IN HOURS 24.0
EXTERNAL DC OPERATING VOLTAGE IN VOLTS 28.0 NOMINAL SINGLE VOLTAGE
EXTERNAL AC OPERATING VOLTAGE IN VOLTS 115.0 NOMINAL SINGLE VOLTAGE
OPERATING AC FREQUENCY IN HERTZ 400.0 NOMINAL SINGLE VOLTAGE
PHASE SINGLE
INCLOSURE TYPE ENCASED
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 14.375 INCHES NOMINAL
OVERALL HEIGHT 7.625 INCHES NOMINAL
OVERALL WIDTH 10.125 INCHES NOMINAL
MANUFACTURERS CODE 00724
DESIGN CONTROL REFERENCE 01-00398-001

Restrictions/Controls & Freight Information | NSN 5821-00-068-9696

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:CMunitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories.
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062120 GENERATORS/MOTORS/PARTS NOI SUB3
Less than car load rating D 200
Less than truck load rating Q 70.0
Water commodity Code 738 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5821-00-068-9696

Category Code Description
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityTAF Recoverable Assembly Management System (AFRAMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each