NSN 5820-01-141-7953 AN/PRC-104A, ANPRC104A, 75502A0050
Product Details | RADIO SET
5820-01-141-7953 A fixed number of components and/or items, not all having the same basic name, utilizing radio frequency electromagnetic waves in space to carry two-way intelligence. Excludes RADAR SET; FACSIMILE SET; RECEIVING SET, RADIO; RECEIVER-TRANSMITTER, RADIO; and RECEIVING SET, TELEVISION.20558200061Radio and Television Communication Equipment, Except Airborne58210054Radio and Television Communication Equipment, Airborne58250043Radio Navigation Equipment, Except Airborne58260036Radio Navigation Equipment, Airborne77300051Phonographs, Radios, and Television Sets: Home Type
Part Alternates: AN/PRC-104A, ANPRC104A, 75502A0050, 5820-01-141-7953, 01-141-7953, 5820011417953, 011417953
Communication, Detection, and Coherent Radiation Equipment | Radio and Television Communication Equipment, Except Airborne
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
58 | 05 NOV 1982 | 01-141-7953 | 19533 ( RADIO SET ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5820-01-141-7953
Technical Data | NSN 5820-01-141-7953
Characteristic | Specifications |
---|---|
RECEIVER FREQUENCY RATING | 2.0 MEGAHERTZ MINIMUM AND 29.9 MEGAHERTZ MAXIMUM |
TRANSMITTER FREQUENCY RATING | 2.0 MEGAHERTZ MINIMUM AND 29.9 MEGAHERTZ MAXIMUM |
MAXIMUM POWER DISSIPATION RATING | 20.0 MILLIWATTS |
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
FREQUENCY RATING | 5000.0 HERTZ NOMINAL |
DC VOLTAGE RATING | 20.0 VOLTS MINIMUM AND 32.0 VOLTS MAXIMUM |
INTERNAL BATTERY ACCOMMODATION | INCLUDED |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME | RADIO SET |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER | AN/PRC-104A |
Restrictions/Controls & Freight Information | NSN 5820-01-141-7953
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | C | Munitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories. |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | N | The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input). |
Category | Code | Description |
---|---|---|
NMF Description | 116030 | MACHINES ETC DATA PROCESSING |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | CL | U.S. Army Communications-Electronics Fort Monmouth, NJ 07703-5006 |
Air Dimension Code | Z | Shipment is not a consolidation, but does exceed 72 inches in one or more dimensions. |
Air Commodity | 2 | Arms/Weapons (all types including Inert Component Parts). When a 2 is indicated in the first position, then the special handling code must be determined from table 85 , part 1. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 2 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5820-01-141-7953
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | G | Communications and Electronics Equipment, Electronics Materiel |
Appropriation and Budget Activity | P | Communications and Electronics Equipment (except Safeguard) |
Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
Specific Group/Generic Code | R | Tactical and Strategic Communications |
Weapons Systems/End Item or Homogeneous Group | RC | Multi-channel Radios A |
Accounting Requirements Code | N | Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items. |
Source of Supply | B16 | US Army Communications-Electronics Command and Fort Monmouth Fort Monmouth, NJ 07703-5016 |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Stores Account Code | 3 | Marine Corps Appropriation Stores Account Principal Item. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | 4 | Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665 |
Echelon Management Code | 3 | Headquarters Marine Corps All Marine Corps-managed items managed by the ICP on a |
Echelon Identification Code | A | Type 1 End Items 1 |
Operational Test Code | 0 | Items of supply which when properly packaged and placed in storage, do not require the performance of special procedures while in storage, nor prior to issue, and for which it has been determined that existing Care in Stores quality control procedures are adequate. |
Source of Supply | MPB | Commanding General Marine Corps Logistics Command 566-2, Bldg. 3700 Albany, GA 31704-5000 |
Agency | DM | U.S. Marine Corps |
Service Organization | L | Lead Service - 22 (Repairable) |
Acquisition Advice Codes | B | INVENTORY CONTROL POINT (ICP)-REGULATED (Service/Agency use only.) # Issue, transfer, or shipment is controlled by the ICP. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedure. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |