Product Details | OSCILLOSCOPE

5820-01-118-7185 A test instrument which is designed to give visual indications on an LCD display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an LCD display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see INDICATOR (2) (as modified); MONITOR (as modified); and RECORDER (as modified). See also OSCILLOGRAPH.

Part Alternates: 011187185

Communication, Detection, and Coherent Radiation Equipment | Radio and Television Communication Equipment, Except Airborne

Supply Group (FSG) NSN Assign. NIIN
58 01-118-7185

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5820-01-118-7185

Technical Data | NSN 5820-01-118-7185

Characteristic Specifications
SCREEN SIZE 8 BY 10 CENTIMETERS
BEAM QUANTITY 1
SWEEP CIRCUITS INCLUDED
GENERATOR DRIVEN FEATURE INCLUDED
SWEEP CIRCUIT TYPE HORIZONTAL
SWEEP FREQUENCY RANGE 0.0 TO 20.0 MEGAHERTZ
SINGLE TRIGGER SWEEP DURATION 0.050 SECONDS MINIMUM AND 2.5 SECONDS MAXIMUM
TRIGGER SWEEP VOLTAGE AMPLITUDE RATING 300.0 MEGAVOLTS NOMINAL
TRIGGER SWEEP POLARITY SWITCH INCLUDED
TRIGGER SWEEP MARKER INTERVALS 0.1 SEC,0.2 SEC,0.5 SEC,1.0 SEC; 0.1 MS,0.2 MS,0.5 MS,1.0 MS,2.0 MS,5.0 MS,10.0 MS,20.0 MS,50.0 MS ; 0.5 US,1.0 US,2.0 US,5.0 US,10.0 US,20.0 US,50.0 US
EXPANDED SWEEP NOT PROVIDED
AMPLIFIER DEFLECTION SENSITIVITY PROVISION PROVIDED
VERTICAL DEFLECTION SENSITIVITY VOLTAGE RATING 0.005 VOLTS MINIMUM RMS PER CENTIMETER AND 20.0 VOLTS MAXIMUM RMS PER CENTIMETER
HORIZONTAL DEFLECTION SENSITIVITY VOLTAGE RATING 15.0 VOLTS NOMINAL RMS PER CENTIMETER
INPUT INTENSITY MODULATION FEATURE PROVIDED
VISUAL MODULATION SENSITIVITY VOLTAGE RATING 2.0 VOLTS NOMINAL
VISUAL BLANKING SENSITIVITY VOLTAGE RATING 60.0 VOLTS NOMINAL
PLATE DIRECT CONNECTION DEFLECTION SENSITIVITY PROVISION PROVIDED
DIRECT CONNECTION VERTICAL DEFLECTION SENSITIVITY VOLTAGE RATING 7.0 VOLTS NOMINAL RMS PER INCH
DIRECT CONNECTION HORIZONTAL DEFLECTION SENSITIVITY VOLTAGE RATING 15.0 VOLTS NOMINAL RMS PER INCH
FREQUENCY RESPONSE RATING PROVIDED
X-AXIS FREQUENCY RESPONSE RATING 2.0 HERTZ MINIMUM AND 5000.0 HERTZ MAXIMUM
Y-AXIS FREQUENCY RESPONSE RATING 0.0 MEGAHERTZ MINIMUM AND 15.0 MEGAHERTZ MAXIMUM
Z-AXIS FREQUENCY RESPONSE RATING 500.0 HERTZ MINIMUM AND 0.500000 HERTZ MAXIMUM
AMPLIFIER INPUT IMPEDANCE RATING PROVISION PROVIDED
X-AXIS INPUT IMPEDANCE RATING 10000.0 OHMS NOMINAL
Y-AXIS INPUT IMPEDANCE RATING 1.0 MEGOHMS NOMINAL
Z-AXIS INPUT IMPEDANCE RATING 1.0 MEGOHMS NOMINAL
AMPLITUDE CALIBRATING VOLTAGE WAVEFORM SQUARE WAVE
CALIBRATING PEAK TO PEAK AMPLITUDE 1.0 VOLTS NOMINAL
ACCURACY RANGE IN PERCENT -2.0 TO 2.0
MEASUREMENT RANGE QUANTITY 1
MEASUREMENT RANGE STEPS 5MV TO 20V STEPS
CALIBRATED SCREEN SCALE INCLUDED
GRADUATION INTERVAL GRADUATED IN V/CM ON Y AXIS AND TIME/CM ON X AXIS
TRACE STORAGE TUBE NOT INCLUDED
CAMERA RECORDING DEVICE ACCOMMODATION PROVIDED

Restrictions/Controls & Freight Information | NSN 5820-01-118-7185

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).