Product Details | RADIO FREQUENCY TUNING UNIT

5820-00-642-7019 An electronic device consisting of the necessary elements to establish the frequency or frequency range of two or more tuned circuits to predetermined value or range. It may have facilities for calibration adjustments. There are no integral facilities for continuous variation of the frequency over the entire range of the item. It is generally used with an external variable capacitor or inductor which will effect the continuous variation of the frequency. This item is used to facilitate rapid band or channel changes in radio receivers, transmitters, amplifiers or similar devices. It does not include electron tubes. See also COIL ASSEMBLY, RADIO FREQUENCY and TUNER, RADIO FREQUENCY.20358200061Radio and Television Communication Equipment, Except Airborne58950037Miscellaneous Communication Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: 326R306ISSUEA, 5820-00-642-7019, 00-642-7019, 5820006427019, 006427019

Communication, Detection, and Coherent Radiation Equipment | Radio and Television Communication Equipment, Except Airborne

Supply Group (FSG) NSN Assign. NIIN
58 01 JAN 1963 00-642-7019

Drawings & Photos | NSN 5820-00-642-7019


Cross Reference | NSN 5820-00-642-7019

Part Number Cage Code Manufacturer
326R306ISSUEA 13848 JOHNSON E F CO COMCO/COMMUNICATIONS CO DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5820-00-642-7019

Technical Data | NSN 5820-00-642-7019

Characteristic Specifications
FREQUENCY PER CHANNEL 2.0 MEGAHERTZ MINIMUM 1ST OPERATING CHANNEL 4.0 MEGAHERTZ MAXIMUM 1ST OPERATING CHANNEL 4.0 MEGAHERTZ MINIMUM 2ND OPERATING CHANNEL 6.0 MEGAHERTZ MAXIMUM 2ND OPERATING CHANNEL 6.0 MEGAHERTZ MINIMUM 3RD OPERATING CHANNEL 8.0 MEGAHERTZ MAXIMUM 3RD OPERATING CHANNEL
ATTENUATION IN DECIBELS NOT RATED
AVERAGE POWER RATING PER CHANNEL NOT RATED
SIGNAL VOLTAGE RATING PER CHANNEL NOT RATED
OVERALL GAIN NOT RATED
IMPEDANCE RATING PER CHANNEL NOT RATED
OPERATING CONTROL METHOD MANUAL
CONTROL TYPE LOCAL
MAXIMUM CONTINUOUS OPERATING TIME IN HOURS NOT RATED
AVERAGE LIFE MEASUREMENT NOT RATED
MAXIMUM OPERATING ALTITUDE RATING NOT RATED
OPERATING TEMP RANGE NOT RATED
VIBRATION RESISTANCE RANGE IN HERTZ NOT RATED
SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS NOT RATED
INCLOSURE TYPE ENCASED
INSTALLATION DESIGN MECHANICAL
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 2.875 INCHES NOMINAL
OVERALL HEIGHT 2.000 INCHES NOMINAL
OVERALL WIDTH 2.750 INCHES NOMINAL
MANUFACTURERS CODE 13848
DESIGN CONTROL REFERENCE 326R306ISSUEA

Restrictions/Controls & Freight Information | NSN 5820-00-642-7019

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063035 SETS RADIO/TV AND RELATED ARTICLES
Less than car load rating G 125
Less than truck load rating G 125.0
Water commodity Code 758 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5820-00-642-7019

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each