NSN 5820-00-421-1154 T1233VGSQCHANNEL1456, T1233VGSQCHANNEL1486, 6143961456
Product Details | RADIO TRANSMITTER
5820-00-421-1154 A single component specifically designed to generate electrical signals of specific frequency and form, which, when fed to an antenna, will propagate radio frequency electromagnetic waves in space. May include facilities for amplification and/or integral modulator. See also TRANSMITTER, RADAR.20258200061Radio and Television Communication Equipment, Except Airborne58210054Radio and Television Communication Equipment, Airborne
Part Alternates: T1233VGSQCHANNEL1456, T1233VGSQCHANNEL1486, 6143961456, 614396-1456, 6143961486, 614396-1486 , 5820-00-421-1154, 00-421-1154, 5820004211154, 004211154
Communication, Detection, and Coherent Radiation Equipment | Radio and Television Communication Equipment, Except Airborne
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
58 | 09 FEB 1972 | 00-421-1154 | 19436 ( TRANSMITTER, RADIO ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5820-00-421-1154
Technical Data | NSN 5820-00-421-1154
Characteristic | Specifications |
---|---|
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
DC VOLTAGE RATING | 28.0 VOLTS NOMINAL |
INTERNAL BATTERY ACCOMMODATION | INCLUDED |
OVERALL LENGTH | 3.304 INCHES NOMINAL |
OVERALL DIAMETER | 2.750 INCHES NOMINAL |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME | TRANSMITTER,RADIO |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER | T-1233V/GSQ CHANNEL 1456 |
TRANSMITTER EMISSION TYPE | F9 |
POWER OUTPUT | 2.000 WATTS NOMINAL |
TRANSMITTER BAND QUANTITY | 1 |
TRANSMITTER CHANNEL QUANTITY | 1 |
FREQUENCY CONTROL TYPE | CRYSTAL |
MANUFACTURERS CODE | 91417 |
DESIGN CONTROL REFERENCE | 614396-1456 |
Restrictions/Controls & Freight Information | NSN 5820-00-421-1154
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | C | Munitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories. |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 062820 | RADIO/TV TRANSMIT/RECEIVE SETS SUB3 |
Less than car load rating | ||
Less than truck load rating | E | 175.0 |
Water commodity Code | 72D | unknown |
Originating Activity Code | CL | U.S. Army Communications-Electronics Fort Monmouth, NJ 07703-5006 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | 2 | Arms/Weapons (all types including Inert Component Parts). When a 2 is indicated in the first position, then the special handling code must be determined from table 85 , part 1. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 2 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5820-00-421-1154
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | G | Communications and Electronics Equipment, Electronics Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 3 | INSURANCE ITEMS. This code will identify items for which there may be occasional intermittent demands not sufficiently repetitive to warrant classification as regular stock items, but for which prudence requires that nominalquan tity be stocked for the reason that the essentiality of the item and the long lead time required to obtain such items by purchase would create an unacceptable situation if no stock were carried. |
Specific Group/Generic Code | S | Surveillance Target Acquisition and Night Observation (STANO) |
Weapons Systems/End Item or Homogeneous Group | SB | Anti-Intrusion |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | B16 | US Army Communications-Electronics Command and Fort Monmouth Fort Monmouth, NJ 07703-5016 |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Stores Account Code | 2 | Marine Corps Appropriation Stores Account Secondary Items. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | 4 | Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665 |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Operational Test Code | 0 | Items of supply which when properly packaged and placed in storage, do not require the performance of special procedures while in storage, nor prior to issue, and for which it has been determined that existing Care in Stores quality control procedures are adequate. |
Physical Category Code | 1 | Bin |
Source of Supply | MPB | Commanding General Marine Corps Logistics Command 566-2, Bldg. 3700 Albany, GA 31704-5000 |
Agency | DM | U.S. Marine Corps |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | D | Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level. |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |