NSN 5430-01-294-0276 F990150, 108430, 01-294-0276
Product Details | COLLAPSIBLE FABRIC TANK
5430-01-294-0276 A receptacle constructed of either canvas or nylon material and of various shapes. It may or may not be furnished with a cover and/or ground cloth. Staves and guy ropes are usually furnished to enable assembly of the item. It is used for the storage of bulk liquids, such as gasoline, oil or water. Tank may be equipped with pipe fittings. Excludes tanks installed as an integral part of another system, trailer or truck mounted tanks designed for transporting liquids, and DRUM, FABRIC, COLLAPSIBLE.
Part Alternates: F990150, 108430, 5430-01-294-0276, 01-294-0276, 5430012940276, 012940276
Prefabricated Structures and Scaffolding | Storage Tanks
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
54 | 10 FEB 1989 | 01-294-0276 | 14212 ( TANK, FABRIC, COLLAPSIBLE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5430-01-294-0276
Related Products | NSN 5430-01-294-0276
Technical Data | NSN 5430-01-294-0276
Characteristic | Specifications |
---|---|
MATERIAL | PLASTIC, POLYESTER RESIN, GLASS FIBER BASE |
COATING MATERIAL | PLASTIC, POLYESTER RESIN, GLASS FIBER BASE |
COATING MATERIAL LOCATION | INSIDE SURFACE AND OUTSIDE SURFACE |
TANK CAPACITY | 1000.0 GALLONS |
OVERALL DEPTH | 3.000 FEET NOMINAL |
OVERALL LENGTH | 9.500 FEET NOMINAL |
OVERALL WIDTH | 6.500 FEET NOMINAL |
STAVES | INCLUDED |
STAKES | INCLUDED |
GUY WIRES | INCLUDED |
SPRAY BAR ATTACHMENT | INCLUDED |
COVER | PROVIDED |
Restrictions/Controls & Freight Information | NSN 5430-01-294-0276
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | 4 | LOW SENSITIVITY (SRC IV) - UNCLASSIFIED AA&E. (SEE NOTES (4), (5), AND (6) BELOW). |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |
Management | NSN 5430-01-294-0276
Category | Code | Description |
---|---|---|
Cognizance Codes | 2C | Major construction and civil engineering equipment Civil Engineer Support Office 2D |
Issue Repair, or Requisition | AH | Submit/refer requisitions to CESO (Civil Engineer Support Office) CBC Port Hueneme. |
Special Material Content | 9 | Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions |
Source of Supply | R41 | Naval Facilities Expenditionary Logistics Center Code N42 Bldg 1000 23rd Ave Port Hueneme, CA 93043 |
Agency | DN | Department of the Navy |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | V | 2C Cog CEEI Material (major end item) |
Acquisition Advice Codes | A | SERVICE/AGENCY-REGULATED (Service/Agency use only.) # Issue, transfer or shipment is controlled by authorities above the ICP level to assure proper and equitable distribution. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedures. |
Controlled Item Code | 4 | LOW SENSITIVITY (SRC IV) - UNCLASSIFIED AA&E. (SEE NOTES (4), (5), AND (6) BELOW). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |