NSN 5340-01-580-6127 CTS120AR, CTS-120-AR, 03002A11162
Product Details | EXTENSION DRAWER SLIDE
5340-01-580-6127 An item designed to be installed in a cabinet or rack to provide support and a sliding or rolling surface for a drawer, or the like. A portion of the slide extends with the drawer to provide support when the drawer is in the open position.
Part Alternates: CTS120AR, CTS-120-AR, 03002A11162, 03002A1116-2, 5340-01-580-6127, 01-580-6127, 5340015806127, 015806127
Hardware and Abrasives | Hardware, Commercial
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
53 | 21 DEC 2009 | 01-580-6127 | 28191 ( SLIDE, DRAWER, EXTENSION ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5340-01-580-6127
Related Products | NSN 5340-01-580-6127
Technical Data | NSN 5340-01-580-6127
Characteristic | Specifications |
---|---|
CLOSED LENGTH | 20.000 INCHES NOMINAL |
END ITEM IDENTIFICATION | LAV-C2A2;2355-01-539-3589 |
MATERIAL | STEEL BODY |
PART NAME ASSIGNED BY CONTROLLING AGENCY | SOLID BEARING 20 INCH 3-SECTION SLIDE,NON-PIVOTING |
STYLE DESIGNATOR | 3 - MEMBER |
SIDE FOR WHICH DESIGNED | LEFT HAND |
EXTENDED LENGTH | 43.875 INCHES NOMINAL |
SPECIAL FEATURES | SOLID BEARING 20 IN 3-SECTION SLIDE;AUTOMATIC RELEASE NON-PIVOTING SLIDE;INCLUDES ALL MOUNTING HARDWARE-REAR MOUNT BRACKET(B-131);BAR NUTS (CA8056-06-0020) AND NO.10-32 SCREWS AND KEPS NUTS |
FEATURES PROVIDED | SOLID AND SELF-LOCKING AND SCREW |
MOUNTING METHOD | BRACKET |
WIDTH | 3.410 INCHES NOMINAL |
HEIGHT | 0.384 INCHES NOMINAL |
SUPPLEMENTARY FEATURES | ALTERED ITEM DRAWING;DISTRIBUTION STATEMENT C;EXPORT CONTROLLED |
Restrictions/Controls & Freight Information | NSN 5340-01-580-6127
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 096775 | SLIDES DRAWER/SHELF/TABLE STEEL |
Less than car load rating | ||
Less than truck load rating | S | 60.0 |
Water commodity Code | 576 | unknown |
Originating Activity Code | PA | Marine Corps Logistics Base Albany, GA 31704-1128 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | B | Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5340-01-580-6127
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |