NSN 5120-01-601-5194 AS954, AS954 TY1CL1STA , AS954TY1CL1STA
Product Details | SOCKET WRENCH SOCKET
5120-01-601-5194 An item having an internal drive at one end made to fit into the external drive end of a socket wrench handle, torque wrench, or power driven tool. The opposite end consists of various internal wrench shapes such as hexagon or square. It may include an integral universal joint.20251200032Hand Tools, Nonedged, Nonpowered51300024Hand Tools, Power Driven
Part Alternates: AS954, AS954 TY1CL1STA , AS954TY1CL1STA, 12130, 12-130, 456720018007 , 5120-01-601-5194, 01-601-5194, 5120016015194, 016015194
Hand Tools | Hand Tools, Nonedged, Nonpowered
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
51 | 19 JAN 2012 | 01-601-5194 | 03518 ( SOCKET, SOCKET WRENCH ) |
Demand History | NSN 5120-01-601-5194
Part Number | Request Date | QTY | Origin |
---|---|---|---|
12130 | 2021-09-266 | 1 | us |
AS954 | 2021-01-16 | 2 | US |
AS954 | 2019-09-248 | 1 | US |
AS954TY1CL1STA | 2018-09-255 | 1 | US |
Cross Reference | NSN 5120-01-601-5194
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5120-01-601-5194
Related Products | NSN 5120-01-601-5194
Technical Data | NSN 5120-01-601-5194
Characteristic | Specifications |
---|---|
MATERIAL | STEEL OVERALL |
SURFACE TREATMENT | CHROMIUM OVERALL |
STYLE DESIGNATOR | INTERNAL-INTERNAL |
OVERALL LENGTH | 1.496 INCHES NOMINAL |
WRENCHING END OUTSIDE DIAMETER | 1.256 INCHES NOMINAL |
DRIVE END OUTSIDE DIAMETER | 1.256 INCHES NOMINAL |
WRENCHING END OPENING DEPTH | 0.827 INCHES NOMINAL |
WRENCHING SURFACE SIZE | 0.938 INCHES NOMINAL SINGLE END |
WRENCHING SURFACE SHAPE | 12 POINT SINGLE END INTERNAL |
DRIVE SURFACE SIZE | 0.500 INCHES NOMINAL SINGLE END |
DRIVE END SHAPE | SQUARE SINGLE END INTERNAL |
FEATURES PROVIDED | MANUAL TOOL |
SPECIFICATION/STANDARD DATA | 81343-SAE AS954 PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD |
NONDEFINITIVE SPEC/STD DATA | 1 TYPE AND |
Restrictions/Controls & Freight Information | NSN 5120-01-601-5194
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |
Management | NSN 5120-01-601-5194
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | E | General Supplies (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | GSA | General Services Administration Washington, D.C. 20406 |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | M | HANDTOOLS AND SHOP EQUIPMENT |
Shelf Life Code | 0 | Nondeteriorative |
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 2 | Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items. |
Materiel Management Code | 0 | GSA MaterielItems cataloged by the Marine Corps and managed by the General Services Administration. |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Physical Category Code | 1 | Bin |
Source of Supply | GSA | General Services Administration Washington, D.C. 20406 |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |