NSN 4920-00-508-4082 MARK54M0D0, T945525, T945-525
Product Details | FIRE CONTROL SYSTEM TEST SET
4920-00-508-4082 A test set primarily designed for use in making examinations of a fire control system. Excludes TEST SET, BOMB DIRECTOR.20249200058Aircraft Maintenance and Repair Shop Specialized Equipment49310062Fire Control Maintenance and Repair Shop Specialized Equipment
Part Alternates: MARK54M0D0, T945525, T945-525, LD286927, 1368822, 1D286927, 4920-00-508-4082, 00-508-4082, 4920005084082, 005084082
Maintenance and Repair Shop Equipment | Aircraft Maintenance and Repair Shop Specialized Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
49 | 01 JAN 1963 | 00-508-4082 | 03638 ( TEST SET, FIRE CONTROL SYSTEM ) |
Cross Reference | NSN 4920-00-508-4082
Part Number | Cage Code | Manufacturer |
---|---|---|
1368822 | 10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT |
1D286927 | 10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT |
LD286927 | 10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT |
LD286927 | 30003 | NAVAL AIR SYSTEMS COMMAND |
MARK54M0D0 | 10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT |
MARK54M0D0 | 30003 | NAVAL AIR SYSTEMS COMMAND |
T945-525 | 10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT |
T945-525 | 30003 | NAVAL AIR SYSTEMS COMMAND |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 4920-00-508-4082
Related Products | NSN 4920-00-508-4082
Technical Data | NSN 4920-00-508-4082
Characteristic | Specifications |
---|---|
TEST TYPE FOR WHICH DESIGNED | MEASUREMENT OF VOLTAGE,CURRENT & FREQUENCY |
OPERATING TEST CAPABILITY | MEASUREMENT OF VOLTAGE,CURRENT AND FREQUENCY; FREQUENCY METER,RANGE 380 TO 420 HERTZ,ACCURACY PORM 1 PCT; MICROAMMETER,RANGE 50-0-50 UA DC,95 MV DROP ACROSS TERMINALS SENSITIVITY; MILLIAMMETER,RANGE 10-0-10 MA DC,50 MV DROP ACROSS TERMINALS SENSITIVITY; QUALITY INDICATOR,RANGE 45-0-45 DEG SENSITIVITY 30 UA DC FOR 45 DEG DEFLECTION FROM NULL; VARIABLE TRANSFORMER,INPUT 115 VAC,OUTPUT 0 TO 135 VAC,MAX CURRENT 3 AMP,FREQUENCY RANGE 350 TO 1200 HERTZ; VOLTMETER,RANGE 0 TO 15 VDC,SENSITIVITY 200 OHMS PER V; VOLTMETER,RANGE 0 TO 150 VAC,SENSITIVITY 75 OHMS PER V,FREQUENCY 400 HERTZ |
AC VOLTAGE RATING | 115.0 VOLTS NOMINAL |
FREQUENCY RATING | 400.0 HERTZ NOMINAL |
PHASE | SINGLE |
INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
INCLOSURE FEATURE | SINGLE ITEM W/CARRYING CASE |
MATERIAL AND LOCATION | ALUMINUM CARRYING CASE |
HEIGHT | 13.875 INCHES NOMINAL |
LENGTH | 19.531 INCHES NOMINAL |
WIDTH | 17.531 INCHES NOMINAL |
III FSC APPLICATION DATA | TEST SET,SPECIALLY DESIGNED,ACFT |
MANUFACTURERS CODE | 10001 |
DESIGN CONTROL REFERENCE | LD286927 |
Restrictions/Controls & Freight Information | NSN 4920-00-508-4082
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | W | Rating Variable |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 4920-00-508-4082
Category | Code | Description |
---|---|---|
Cognizance Codes | 6R | Aeronautical ground support equipment (reparable or investment type material) Naval Inventory Control Point, Philadelphia |
Special Material ID | EF | FIGHTERAIRCRAFT(F8) |
Issue Repair, or Requisition | BS | Submit/refer requisitions to NAVICP PHIL. |
Source of Supply | N32 | Naval Inventory Control Point Philadelphia, PA 19111-5098 |
Agency | DN | Department of the Navy |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | X | Special Program Reparables |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |