Product Details | TUBE TO BOSS ELBOW

4730-01-621-7795 A fitting that forms an angle of less that 180 degrees (3.141 radians) from a straight flow. One connecting end has machine threads (straight threads other than pipe or hose series) designed to accommodate a tube or is unthreaded and designed to accommodate a tube. The other end has external or internal machine threads (straight threads other than pipe or hose series) and is designed to facilitate a gasket, preformed packing, washer, or the like, to form a seal at the boss. It may have side or heel inlet(s). It is designed to connect a tube or tube fitting to a boss or boss fitting on items such as tanks, housings, valve fittings, or the like.

Part Alternates: WH30SMOMDCF , 4730-01-621-7795, 01-621-7795, 4730016217795, 016217795

Pipe, Tubing, Hose, and Fittings | Hose, Pipe, Tube, Lubrication, and Railing Fittings

Supply Group (FSG) NSN Assign. NIIN
47 2013260 01-621-7795

Cross Reference | NSN 4730-01-621-7795

Part Number Cage Code Manufacturer
WH30SMOMDCF 1KPD5 PARKER HANNIFIN CORP TUBE FITTING DIV
WH30SMOMDCF 30780 PARKER-HANNIFIN CORPORATION DBA TUBE FITTINGS DIVISION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4730-01-621-7795

Technical Data | NSN 4730-01-621-7795

Characteristic Specifications
MATERIAL STEEL BODY
SURFACE TREATMENT ZINC BODY
STYLE DESIGNATOR ELBOW
CONNECTION TYPE THREADED EXTERNAL TUBE ALL ENDS
CONNECTION STYLE PLAIN (PIPE) ALL ENDS
THREAD SERIES DESIGNATOR ISO M 1ST END
NOMINAL THREAD SIZE 42.0 MILLIMETERS 1ST END
LEG LENGTH 64.0 MILLIMETERS NOMINAL ALL ENDS
FLOW ANGLE 90.0 DEGREES
SEAT TYPE GASKET

Restrictions/Controls & Freight Information | NSN 4730-01-621-7795

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information