NSN 4730-00-889-1664 30N6603316SSM0D, 566D212PC14, 8204445910PC43
Product Details | TUBE COUPLING
4730-00-889-1664 A straight fitting 12 inches (304 mm) long or under having the same or different type of connection of the same size on both ends. It is designed to join a tube or tube fitting to another tube or tube fitting. Excludes fittings with threaded external connections on both ends. Excludes NIPPLE, PIPE.
Part Alternates: 30N6603316SSM0D, 566D212PC14, 8204445910PC43, 820-4445910PC43, 4730-00-889-1664, 00-889-1664, 4730008891664, 008891664
Pipe, Tubing, Hose, and Fittings | Hose, Pipe, Tube, Lubrication, and Railing Fittings
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
47 | 01 JAN 1962 | 00-889-1664 | 06078 ( COUPLING, TUBE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 4730-00-889-1664
Related Products | NSN 4730-00-889-1664
Technical Data | NSN 4730-00-889-1664
Characteristic | Specifications |
---|---|
MATERIAL | STEEL COMP 316 OVERALL |
MATERIAL DOCUMENT AND CLASSIFICATION | QQ-S-763,CL 316 FED SPEC SINGLE MATERIAL RESPONSE OVERALL |
NOMINAL OVERALL LENGTH | 3.000 INCHES |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | CLEANED IN ACCORDANCE WITH MIL-STD-767A |
CRITICALITY CODE JUSTIFICATION | ZZZY |
MANUFACTURERS CODE | 80064 |
DESIGN CONTROL REFERENCE | 820-4445910PC43 |
Restrictions/Controls & Freight Information | NSN 4730-00-889-1664
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | F | Munitions List Item or Commerce Control List Item. Demilitarization required. Demilitarization Instructions to be furnished by the Item/Technical Manager. |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | C | The item has critical features such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input). |
Category | Code | Description |
---|---|---|
No Freight Information |
Management | NSN 4730-00-889-1664
Category | Code | Description |
---|---|---|
Cognizance Codes | 1H | Consumable material assigned to NAVICP MECH for inventory management Naval Inventory Control Point, Mechanicsburg |
Special Material ID | X3 | Nuclear Reactor Plant (NRP) material under the technical cognizance of the NAVSEA 08 special designed, manufactured and/or treated for use in a NRP or controls thereof. This category includes all other NRP items which are not coded X2 or X4. |
Issue Repair, or Requisition | BL | Submit/refer requisitions to NAVICP MECH. Centralized control for issue of repair parts for specific programs/equipments. |
Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Reparability | M | Medium Demand Velocity Items (consumables) |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |