Product Details | INCINERATOR

4540-01-581-2479 A furnace or oven, usually of a substantial and heavy construction, designed for the carbonizing of refuse, garbage, and solid constituents of matter. Excludes BURNER, RUBBISH.

Part Alternates: MEDIBURN 30 , MEDIBURN30, 0MEDI230, 0MEDI-230, 4540-01-581-2479, 01-581-2479, 4540015812479, 015812479

Plumbing, Heating, and Waste Disposal Equipment | Waste Disposal Equipment

Supply Group (FSG) NSN Assign. NIIN
45 11 JAN 2010 01-581-2479

Demand History | NSN 4540-01-581-2479

Part Number Request Date QTY Origin
4540-01-581-2479 2022-07-199 1 GE
4540-01-581-2479 2022-06-179 1 US
0MEDI230 2022-06-173 1 US
0MEDI230 2022-06-172 1 US
4540-01-581-2479 2020-05-137 2 AE
4540-01-581-2479 2018-10-281 2 United Arab Emirates

Cross Reference | NSN 4540-01-581-2479

Part Number Cage Code Manufacturer
0MEDI-230 01YQ3 ELASTEC, INC. DBA ELASTEC AMERICAN MARINE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4540-01-581-2479

Technical Data | NSN 4540-01-581-2479

Characteristic Specifications
OVERALL LENGTH 79.000 INCHES NOMINAL
SUPPLEMENTARY FEATURES INCINERATES UP TO 30KG AN HR; LINER MATERIAL-REPLACEABLE CERAMICS; DUAL CHAMBER COMBUSTION AND HIGH EXHAUST TEMP IN EXCESS OF 1000C (1832F); HEIGHT-W STACK-100IN (254CM), W/O STACK-82IN (208CM); WEIGHT-2.440 LBS (1.107KG); SUGGESTED LOAD VOL-10.5 CU FT (0.30 CU/M) LOAD; FUEL AND POWER CONSUMPTION-ELECTRICAL-VARIABLE, FUEL-2-3 GAL/HOUR (7-11 LITERS/HOUR)
OVERALL WIDTH 34.000 INCHES NOMINAL
PART NAME ASSIGNED BY CONTROLLING AGENCY MEDIBURN 30, PORTABLE MEDICAL WASTE INCINERATOR

Restrictions/Controls & Freight Information | NSN 4540-01-581-2479

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information