Product Details | CENTRIFUGAL FAN

4140-01-130-7858 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.20216600062Aircraft Air Conditioning, Heating, and Pressurizing Equipment41400043Fans, Air Circulators, and Blower Equipment

Part Alternates: A159AC, A15-9AC, A159ACE, A15-9ACE, 02484027, 024840-27, 29D210243NM1, 29D2-102-43N-M1, 8A22, 8A2-2, 4140-01-130-7858, 01-130-7858, 4140011307858, 011307858

Refrigeration, Air Conditioning, and Air Circulating Equipment | Fans, Air Circulators, and Blower Equipment

Supply Group (FSG) NSN Assign. NIIN
41 28 APR 1982 01-130-7858

Drawings & Photos | NSN 4140-01-130-7858


Cross Reference | NSN 4140-01-130-7858

Part Number Cage Code Manufacturer
024840-27 35197 PHILIPS INDUSTRIES INC
29D2-102-43N-M1 98437 ELLIS & WATTS INTERNATIONAL, LLC
8A2-2 94987 CUBIC DEFENSE APPLICATIONS, INC.
A15-9AC 35197 PHILIPS INDUSTRIES INC
A15-9ACE 35197 PHILIPS INDUSTRIES INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4140-01-130-7858

Technical Data | NSN 4140-01-130-7858

Characteristic Specifications
STYLE DESIGNATOR 50 FIXED, RECTANGULAR OUTLETS
DIAMETER 15.000 INCHES NOMINAL
LENGTH 22.500 INCHES NOMINAL
QUANTITY 1
MATERIAL STEEL OVERALL
DRIVE TYPE BELT
OUTLET LOCATION BOTTOM
DISCHARGE DIRECTION HORIZONTAL
MANUFACTURERS CODE 35197
DESIGN CONTROL REFERENCE A15-9ACE

Restrictions/Controls & Freight Information | NSN 4140-01-130-7858

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061920 FANS ELEC NOI IN BARREL/BOX/CRATE
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 752 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 4140-01-130-7858

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each