Product Details | CENTRIFUGAL FAN

4140-00-267-1710 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.20216600062Aircraft Air Conditioning, Heating, and Pressurizing Equipment41400043Fans, Air Circulators, and Blower Equipment

Part Alternates: 570575, 8V8475, 8V8475C5A4D5CW, 4140-00-267-1710, 00-267-1710, 4140002671710, 002671710

Refrigeration, Air Conditioning, and Air Circulating Equipment | Fans, Air Circulators, and Blower Equipment

Supply Group (FSG) NSN Assign. NIIN
41 01 JAN 1963 00-267-1710

Drawings & Photos | NSN 4140-00-267-1710


Cross Reference | NSN 4140-00-267-1710

Part Number Cage Code Manufacturer
570575 80064 NAVAL SHIP SYSTEMS COMMAND
8V8475 09519 NEW PHILADELPHIA FAN CO BUFFALO FORGE MARINE FANS
8V8475 75477 HOWDEN NORTH AMERICA INC. DBA HOWDEN NORTH AMERICA
8V8475C5A4D5CW 09519 NEW PHILADELPHIA FAN CO BUFFALO FORGE MARINE FANS
8V8475C5A4D5CW 75477 HOWDEN NORTH AMERICA INC. DBA HOWDEN NORTH AMERICA

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4140-00-267-1710

Technical Data | NSN 4140-00-267-1710

Characteristic Specifications
STYLE DESIGNATOR 50 FIXED, RECTANGULAR OUTLETS
LENGTH 45.437 INCHES NOMINAL
OUTLET INSIDE WIDTH 10.562 INCHES NOMINAL
OUTLET INSIDE HEIGHT 13.250 INCHES NOMINAL
HEIGHT 38.281 INCHES NOMINAL
MATERIAL STEEL OVERALL
SURFACE TREATMENT ZINC OVERALL
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER 50.0 DEG CELSIUS
ELECTRICAL CONNECTION TYPE TERMINAL BLOCK
PRIME MOVER POWER RATING 5.000 HORSEPOWER
OPERATING SPEED AT RATED CAPACITY IN RPM 1750.0
VOLTAGE IN VOLTS AND CURRENT TYPE 440.0 AC
PHASE THREE
FREQUENCY IN HERTZ 60.0
AIR FLOW RATE 5000.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE 3.0 INCHES OF WATER
ENVIRONMENTAL PROTECTION DRIPPROOF
MOUNTING FACILITY TYPE AND QUANTITY 1 FLANGE
OUTLET LOCATION TOP
DISCHARGE DIRECTION HORIZONTAL
MANUFACTURERS CODE 09519
DESIGN CONTROL REFERENCE 8V8475C5A4D5CW

Restrictions/Controls & Freight Information | NSN 4140-00-267-1710

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061920 FANS ELEC NOI IN BARREL/BOX/CRATE
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 752 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 4140-00-267-1710

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each