Product Details | REFRIGERATION COMPRESSOR

4130-01-518-6705 A centrifugal, reciprocating, or rotary compressor designed to compress refrigerant gas(es) from an initial intake pressure to a final discharge pressure. It is designed to be driven by an independent power source, such as an electric motor, gasoline or diesel engine, or the like. It does not include the prime mover, condenser(s), external filter-drivers, and the like. It may include various peripheral components such as drive pulley, flexible coupling, and the like.

Part Alternates: BO15226, CU64G2564148V, 4130-01-518-6705, 01-518-6705, 4130015186705, 015186705

Refrigeration, Air Conditioning, and Air Circulating Equipment | Refrigeration and Air Conditioning Components

Supply Group (FSG) NSN Assign. NIIN
41 18 MAR 2004 01-518-6705

Cross Reference | NSN 4130-01-518-6705

Part Number Cage Code Manufacturer
BO15226 12867 GSE HOLDINGS INC. DBA ITW MILITARY GSE
CU64G/2.564:1/4.8V 12867 GSE HOLDINGS INC. DBA ITW MILITARY GSE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4130-01-518-6705

Technical Data | NSN 4130-01-518-6705

Characteristic Specifications
GAS FOR WHICH DESIGNED AIR
DISCHARGE FLOW RATE NOT RATED
DISCHARGE PRESSURE NOT RATED
COOLING SYSTEM DESIGN SINGLE
COMPRESSOR COOLING MEDIUM OIL
BRAKE POWER REQUIRED 1.5 HORSEPOWER
STAGE QUANTITY 1
REFRIGERATION FLOW RATE IN TONS PER HOUR NOT RATED
TEMP RATING PER FUNCTION NOT RATED
III UNPACKAGED UNIT WEIGHT 210.00 POUNDS
III UNPACKAGED UNIT LENGTH 22.21 INCHES NOMINAL
III UNPACKAGED UNIT WIDTH 13.90 INCHES NOMINAL
III UNPACKAGED UNIT HEIGHT 12.64 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 4130-01-518-6705

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information