Product Details | INDICATOR PANEL

1680-01-542-8024 A panel designed for indicating purposes only. It does not distribute power nor control the equipment with which it is used. See also PANEL, POWER DISTRIBUTION; SWITCHBOARD, POWER and INDICATOR ASSEMBLY.20912900036Miscellaneous Fire Control Equipment14300037Guided Missile Remote Control Systems167500001677000016800049Miscellaneous Aircraft Accessories and Components18200024Space Vehicle Components58950037Miscellaneous Communication Equipment66950041Combination and Miscellaneous Instruments70500014ADP Components

Part Alternates: 9013611, 90-1361-1, 1680-01-542-8024, 01-542-8024, 1680015428024, 015428024

Aircraft Components and Accessories | Miscellaneous Aircraft Accessories and Components

Supply Group (FSG) NSN Assign. NIIN
16 18 AUG 2006 01-542-8024

Cross Reference | NSN 1680-01-542-8024

Part Number Cage Code Manufacturer
90-1361-1 14550 LUMINESCENT SYSTEMS INC DBA LSI

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 1680-01-542-8024

Technical Data | NSN 1680-01-542-8024

Characteristic Specifications
AC VOLTAGE RATING 5.0 VOLTS MAXIMUM
OVERALL THICKNESS 0.210 INCHES MINIMUM AND 0.250 INCHES MAXIMUM
OVERALL HEIGHT 3.312 INCHES MINIMUM AND 3.344 INCHES MAXIMUM
OVERALL WIDTH 5.687 INCHES MINIMUM AND 5.719 INCHES MAXIMUM
SPECIAL FEATURES LAMP P/N: MS90451-7152,QTY:14,PANEL COLOR: WHITE ON BLACK BACKGROUND
III END ITEM IDENTIFICATION NVIS, CF 18 AIRCRAFT
III PART NAME ASSIGNED BY CONTROLLING AGENCY PANEL,INCANDESCENT TRANSMITTING CONTROL

Restrictions/Controls & Freight Information | NSN 1680-01-542-8024

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information