Product Details | NONCRYSTAL CONTROLLED OSCILLATOR

1430-01-092-4076 An oscillator whose operating frequency(ies) is controlled by an electronic device other than a CRYSTAL UNIT, QUARTZ. For an oscillator controlled by a crystal, see OSCILLATOR (1), CRYSTAL CONTROLLED. See also GENERATOR, SIGNAL; and CALIBRATOR, FREQUENCY. Excludes FREQUENCY SUPPLY, TELEPHONE CARRIER; RESONATOR, TUNING FORK; and OSCILLATOR, PULSE DELAY.20259550038Oscillators and Piezoelectric Crystals59630018Electronic Modules

Part Alternates: 11568597-1, 1430-01-092-4076, 01-092-4076, 1430010924076, 115685971, 010924076

Guided Missiles | Guided Missile Remote Control Systems

Supply Group (FSG) NSN Assign. NIIN
14 26 MAR 1980 01-092-4076

Cross Reference | NSN 1430-01-092-4076

Part Number Cage Code Manufacturer
11568597-1 04164 RAYTHEON ELECTRONIC SYSTEMS, INC
11568597-1 18876 U S ARMY AVIATION AND MISSILE COMMAND

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 1430-01-092-4076

Technical Data | NSN 1430-01-092-4076

Characteristic Specifications
III END ITEM IDENTIFICATION HAWK, IMPROVED, SURFACE TO AIR MISSILES

Restrictions/Controls & Freight Information | NSN 1430-01-092-4076

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating M 85
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code BD U.S. Army Aviation and Missile Command
Redstone Arsenal, AL 35898-5230
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 1430-01-092-4076

Category Code Description
Stores Account Code2Marine Corps Appropriation Stores Account Secondary Items.
Combat Essentiality Code5Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency.
Materiel Management Code6Guided Missiles and Equipment1336, 1337, 1338, 14, 4935, 8140
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Operational Test Code2Items of equipment which require the performance of special procedures are not controlled through the MOWASP special handling suspense routine by USMC/Serial Numbers, (except small arms which are controlled by serial numbers but are assigned OTC 2). Normally OTC 2 items of equipments are small arms, engines (except small engines coded SAC-1 which are non-technical), pumps, generators, electronic equipments and major components/subassemblies of weapon systems, etc. Electronic Circuit Cards and other items which have received Level A packing will only be assigned an OTC when an operational test is mandatory prior to issue.
Physical Category Code1Bin
Source of SupplyMPBCommanding General
Marine Corps Logistics Command
566-2, Bldg. 3700
Albany, GA 31704-5000
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityDReparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level.
Acquisition Advice CodesCSERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each